Poke &Wiggle

Leaderboard

Model

FLUX 3 Action

Black Forest Labs

#1

Rank · PAW-GEN-10

Model information

Website
Website⁠ (opens in a new tab)
Paper
—
Code
black-forest-labs/flux-action⁠ (opens in a new tab)
Parameters
7B
Released
September 2026
Licence
FLUX Kommunity License

PAW-GEN-10

Share of episodes rated Ok or Excellent.

Summary

Overall Success
30%
Evaluations
2700
NominalEvaluated on the placements the model was trained on.InterpolationEvaluated on unseen placements between the training placements.ExtrapolationEvaluated on unseen placements outside the training placements' convex hull.
EnvironmentNominal · D10Trained on ~10 demonstrations per environment.Nominal · D100Trained on ~100 demonstrations per environment.Nominal · D300Trained on ~300 demonstrations per environment.Interpolation · D10Trained on ~10 demonstrations per environment.Interpolation · D100Trained on ~100 demonstrations per environment.Interpolation · D300Trained on ~300 demonstrations per environment.Extrapolation · D10Trained on ~10 demonstrations per environment.Extrapolation · D100Trained on ~100 demonstrations per environment.Extrapolation · D300Trained on ~300 demonstrations per environment.
Basic skills
Sort screws into bins3%#395% CI 1%–17%60%#295% CI 42%–75%77%#195% CI 59%–88%0%#195% CI 0%–11%40%#195% CI 25%–58%53%#195% CI 36%–70%0%#195% CI 0%–11%10%#195% CI 3%–26%3%#195% CI 1%–17%
Datum-corner alignment37%#195% CI 22%–54%93%#195% CI 79%–98%97%#195% CI 83%–99%30%#295% CI 17%–48%83%#195% CI 66%–93%90%#195% CI 74%–97%0%#195% CI 0%–11%10%#295% CI 3%–26%20%#195% CI 10%–37%
Pour screws into the funnel30%#195% CI 17%–48%67%#495% CI 49%–81%80%#495% CI 63%–90%30%#195% CI 17%–48%73%#295% CI 56%–86%90%#195% CI 74%–97%0%#395% CI 0%–11%30%#195% CI 17%–48%37%#395% CI 22%–54%
High precision
Connect DC jack0%#195% CI 0%–11%30%#195% CI 17%–48%33%#495% CI 19%–51%0%#195% CI 0%–11%53%#195% CI 36%–70%47%#195% CI 30%–64%0%#195% CI 0%–11%0%#195% CI 0%–11%23%#195% CI 12%–41%
Route cable through closed hoops0%#195% CI 0%–11%30%#195% CI 17%–48%0%#495% CI 0%–11%0%#195% CI 0%–11%13%#195% CI 5%–30%47%#295% CI 30%–64%0%#195% CI 0%–11%23%#195% CI 12%–41%33%#195% CI 19%–51%
Put tools in standing toolbox0%#295% CI 0%–11%3%#195% CI 1%–17%10%#295% CI 3%–26%0%#195% CI 0%–11%7%#195% CI 2%–21%3%#395% CI 1%–17%0%#195% CI 0%–11%7%#195% CI 2%–21%3%#195% CI 1%–17%
Bimanual
Place loaded boxes in container (bimanual)33%#195% CI 19%–51%50%#395% CI 33%–67%80%#195% CI 63%–90%7%#395% CI 2%–21%50%#395% CI 33%–67%63%#295% CI 46%–78%0%#195% CI 0%–11%7%#195% CI 2%–21%27%#195% CI 14%–44%
Place spray bottles upright, nozzle forward (bimanual handover)67%#195% CI 49%–81%77%#495% CI 59%–88%93%#395% CI 79%–98%23%#195% CI 12%–41%67%#695% CI 49%–81%90%#295% CI 74%–97%27%#195% CI 14%–44%73%#195% CI 56%–86%77%#195% CI 59%–88%
Tool use
Open the toolbox with a screwdriver40%#195% CI 25%–58%7%#595% CI 2%–21%83%#295% CI 66%–93%3%#195% CI 1%–17%20%#395% CI 10%–37%87%#295% CI 70%–95%0%#195% CI 0%–11%10%#295% CI 3%–26%50%#195% CI 33%–67%
Clamp electrical component0%#195% CI 0%–11%0%#695% CI 0%–11%0%#595% CI 0%–11%0%#195% CI 0%–11%0%#495% CI 0%–11%3%#295% CI 1%–17%0%#195% CI 0%–11%0%#195% CI 0%–11%0%#195% CI 0%–11%
Pooled21%#195% CI 17%–26%42%#295% CI 36%–47%55%#195% CI 50%–61%9%#195% CI 7%–13%41%#195% CI 35%–46%57%#195% CI 52%–63%3%#195% CI 1%–5%17%#195% CI 13%–22%27%#195% CI 23%–33%

Data Scaling

Scaling results for FLUX 3 Action: SuccessFLUX 3 Action nominal: D10 21% (95% CI 17%–26%), D100 42% (95% CI 36%–47%), D300 55% (95% CI 50%–61%). FLUX 3 Action interpolation: D10 9% (95% CI 7%–13%), D100 41% (95% CI 35%–46%), D300 57% (95% CI 52%–63%). FLUX 3 Action extrapolation: D10 3% (95% CI 1%–5%), D100 17% (95% CI 13%–22%), D300 27% (95% CI 23%–33%).Success rate (%)03570FLUX 3 Action nominal: 21% (95% CI 17%–26%) on D10FLUX 3 Action nominal: 42% (95% CI 36%–47%) on D100FLUX 3 Action nominal: 55% (95% CI 50%–61%) on D300FLUX 3 Action interpolation: 9% (95% CI 7%–13%) on D10FLUX 3 Action interpolation: 41% (95% CI 35%–46%) on D100FLUX 3 Action interpolation: 57% (95% CI 52%–63%) on D300FLUX 3 Action extrapolation: 3% (95% CI 1%–5%) on D10FLUX 3 Action extrapolation: 17% (95% CI 13%–22%) on D100FLUX 3 Action extrapolation: 27% (95% CI 23%–33%) on D300D10D100D300

Spatial Generalization

Spatial generalization for FLUX 3 Action: SuccessFLUX 3 Action: Nominal 39% (95% CI 36%–43%), Interpolation 36% (95% CI 33%–39%), Extrapolation 16% (95% CI 13%–18%).Success rate (%)03570FLUX 3 Action: 39% (95% CI 36%–43%) on NominalFLUX 3 Action: 36% (95% CI 33%–39%) on InterpolationFLUX 3 Action: 16% (95% CI 13%–18%) on ExtrapolationNominalInterpolationExtrapolation

Per Environment (Success)

Model performance by environmentFLUX 3 Action overall: Sort screws into bins 27%, Datum-corner alignment 51%, Pour screws into the funnel 49%, Connect DC jack 21%, Route cable through closed hoops 16%, Put tools in standing toolbox 4%, Place loaded boxes in container (bimanual) 35%, Place spray bottles upright, nozzle forward (bimanual handover) 66%, Open the toolbox with a screwdriver 33%, Clamp electrical component 0%.Sort screws into binse01Datum-corner alignmente02Pour screws into the funnele03Connect DC jacke04Route cable through closed hoopse05Put tools in standing toolboxe06Place loaded boxes in container (bimanual)e07Place spray bottles upright, nozzle forward (bimanual handover)e08Open the toolbox with a screwdrivere09Clamp electrical componente10Basic skillsHigh precisionBimanualTool use

Training parameters

Starting checkpoint
black-forest-labs/flux-3-action-base
Frozen part
Trunk for the first 1/15 of the run
Total batch size
32
Learning rate
Trunk 1.3e-4Fresh heads 6.5e-4
Schedule
Warmup, then linear to 0 over the last sixth
Action chunk
32
Action space
Relative commanded TCP pose

Compare every model's parameters

Rollouts

Mid-training dataM0
Task-specific dataD300
SpatialInterpolation

One clip per environment from this entry's evaluation, beside where each evaluation episode placed the environment's objects, coloured by its rating. Use the button beside each environment to open its evaluation dataset in the dataset viewer.

  1. Sort screws into bins
    Success
    53%
    Progress
    89%
  2. Pour screws into the funnel
    Success
    90%
    Progress
    97%
  3. Connect DC jack
    Success
    47%
    Progress
    69%
  4. Route cable through closed hoops
    Success
    47%
    Progress
    62%
  5. Open the toolbox with a screwdriver
    Success
    87%
    Progress
    92%
  6. Held-out benchmark environment
    Datum-corner alignment
    Success
    90%
    Progress
    90%
  7. Held-out benchmark environment
    Put tools in standing toolbox
    Success
    3%
    Progress
    50%
  8. Held-out benchmark environment
    Place loaded boxes in container (bimanual)
    Success
    63%
    Progress
    91%
  9. Held-out benchmark environment
    Place spray bottles upright, nozzle forward (bimanual handover)
    Success
    90%
    Progress
    95%
  10. Held-out benchmark environment
    Clamp electrical component
    Success
    3%
    Progress
    37%

Success by dataset size

e01 · Sort screws into bins
D10: 1% (95% CI 0%–6%)D100: 37% (95% CI 27%–47%)D300: 44% (95% CI 35%–55%)D10D100D300
e02 · Datum-corner alignment
D10: 22% (95% CI 15%–32%)D100: 62% (95% CI 52%–72%)D300: 69% (95% CI 59%–78%)D10D100D300
e03 · Pour screws into the funnel
D10: 20% (95% CI 13%–29%)D100: 57% (95% CI 46%–66%)D300: 69% (95% CI 59%–78%)D10D100D300
e04 · Connect DC jack
D10: 0% (95% CI 0%–4%)D100: 28% (95% CI 20%–38%)D300: 34% (95% CI 25%–45%)D10D100D300
e05 · Route cable through closed hoops
D10: 0% (95% CI 0%–4%)D100: 22% (95% CI 15%–32%)D300: 27% (95% CI 19%–37%)D10D100D300
e06 · Put tools in standing toolbox
D10: 0% (95% CI 0%–4%)D100: 6% (95% CI 2%–12%)D300: 6% (95% CI 2%–12%)D10D100D300
e07 · Place loaded boxes in container (bimanual)
D10: 13% (95% CI 8%–22%)D100: 36% (95% CI 26%–46%)D300: 57% (95% CI 46%–66%)D10D100D300
e08 · Place spray bottles upright, nozzle forward (bimanual handover)
D10: 39% (95% CI 29%–49%)D100: 72% (95% CI 62%–80%)D300: 87% (95% CI 78%–92%)D10D100D300
e09 · Open the toolbox with a screwdriver
D10: 14% (95% CI 9%–23%)D100: 12% (95% CI 7%–21%)D300: 73% (95% CI 63%–81%)D10D100D300
e10 · Clamp electrical component
D10: 0% (95% CI 0%–4%)D100: 0% (95% CI 0%–4%)D300: 1% (95% CI 0%–6%)D10D100D300

Success by spatial configuration

e01 · Sort screws into bins
Nominal: 47% (95% CI 37%–57%)Interpolation: 31% (95% CI 22%–41%)Extrapolation: 4% (95% CI 2%–11%)NominalInterp.Extrap.
e02 · Datum-corner alignment
Nominal: 76% (95% CI 66%–83%)Interpolation: 68% (95% CI 58%–77%)Extrapolation: 10% (95% CI 5%–18%)NominalInterp.Extrap.
e03 · Pour screws into the funnel
Nominal: 59% (95% CI 49%–68%)Interpolation: 64% (95% CI 54%–74%)Extrapolation: 22% (95% CI 15%–32%)NominalInterp.Extrap.
e04 · Connect DC jack
Nominal: 21% (95% CI 14%–31%)Interpolation: 33% (95% CI 24%–44%)Extrapolation: 8% (95% CI 4%–15%)NominalInterp.Extrap.
e05 · Route cable through closed hoops
Nominal: 10% (95% CI 5%–18%)Interpolation: 20% (95% CI 13%–29%)Extrapolation: 19% (95% CI 12%–28%)NominalInterp.Extrap.
e06 · Put tools in standing toolbox
Nominal: 4% (95% CI 2%–11%)Interpolation: 3% (95% CI 1%–9%)Extrapolation: 3% (95% CI 1%–9%)NominalInterp.Extrap.
e07 · Place loaded boxes in container (bimanual)
Nominal: 54% (95% CI 44%–64%)Interpolation: 40% (95% CI 30%–50%)Extrapolation: 11% (95% CI 6%–19%)NominalInterp.Extrap.
e08 · Place spray bottles upright, nozzle forward (bimanual handover)
Nominal: 79% (95% CI 69%–86%)Interpolation: 60% (95% CI 50%–70%)Extrapolation: 59% (95% CI 49%–68%)NominalInterp.Extrap.
e09 · Open the toolbox with a screwdriver
Nominal: 43% (95% CI 34%–54%)Interpolation: 37% (95% CI 27%–47%)Extrapolation: 20% (95% CI 13%–29%)NominalInterp.Extrap.
e10 · Clamp electrical component
Nominal: 0% (95% CI 0%–4%)Interpolation: 1% (95% CI 0%–6%)Extrapolation: 0% (95% CI 0%–4%)NominalInterp.Extrap.